# Goniometry and comparison of surface tensions

Case study
# Case study: goniometry and comparison of surface tensions

 One of our customers wanted to measure the contact angle and surface tension of their materials. [Home](https://filab.fr) • [News](https://filab.fr/?post_type=post) • Case study: goniometry and comparison of surface tensions
## The problem?

**Faced with an issue related to the varying behaviour of its liquid product depending on different supplier formulations, one of our pharmaceutical clients wanted to measure the contact angle and surface tension of its samples deposited on three different substrates.**

**The client called on FILAB to verify that the formulation, in this case eye drops, exhibited optimal wetting behaviour on several types of surfaces.**

 

## Summary

 01 Understanding the wetting behaviour of a drop on a substrate [](#cont-01) 02 The approach used [](#cont-02) 03 Conclusion of the study [](#cont-03)   01
## Understanding the wetting behaviour of a drop on a substrate

**Objective:**

The aim of the study is to measure the contact angle and surface tension of several formulations on three different substrates.

1. 1. silicone support,
    2. neutral polyethylene support,
    3. polyethylene support with antimicrobial agent.

![](https://filab.fr/wp-content/uploads/2025/08/ecovadis-70.png)

   02
## The approach used

![](https://filab.fr/wp-content/uploads/2025/08/ecovadis-69.png)

**Approach :**

The technique used is **goniometry**, specifically the **sessile drop method**. A 4 µL drop of water (the model liquid) is placed on each sample. Measurements are taken a few seconds after placement, once the drop has reached a stable state. Each formulation is tested on the appropriate substrates.

For each formulation, surface tensions and contact angles are measured and compared between the different substrates.

   04
## Conclusion of the study

According to the analysis report, the **nature of the substrate significantly influences the behaviour of the formulations**. For the same formulation, the spreading and adhesion properties vary significantly depending on the contact surface.

**Conclusion :**

This study revealed that surface tensions are generally higher on polyethylene substrates than on silicone substrates.

Observation of the droplets shows that the silicone substrate is more hydrophobic than the polyethylene substrate, since the droplet forms a larger contact angle and lower surface tension on this substrate. This simple observation perfectly illustrates the interaction between this formulation and the tested surfaces.

  Need help? Contact our team [](#filab-contact-form)
## Other case studies you may be interested in

### XPS weld passivation

 Comparative study of two XPS weld passivation processes [Learn more +](https://filab.fr/en/blog/2025/12/comparative-study-of-two-xps-weld-passivation-processes.md)
### Yellowing of silicone

 Silicones are now widely used in various fields thanks to their remarkable physical and chemical properties, such as excellent thermal stability, high resistance to oxidation and hydrolysis, and excellent gas permeability. [Learn more +](https://filab.fr/en/blog/2025/12/how-filab-helped-one-of-its-customers-understand-the-yellowing-phenomenon-of-a-silicone.md)
### Piston failure

 A piston is a crucial mechanical component in many mechanical devices and engineering systems. Pistons enable various applications, including: [Learn more +](https://filab.fr/en/blog/2025/12/how-did-filab-help-one-of-its-clients-determine-the-cause-of-steel-piston-failure-at-the-rod-case-study.md) [View all our case studies](https://filab.fr/en/blog-filab.md)
## Services related to the case study

 [## Metal analysis in black mass](https://filab.fr/en/metal-analysis-in-black-mass.md)   [![avis filab](https://filab.fr/wp-content/themes/astra-child/templates/assets/img/avis-verifies.svg) 5/5 ![note filab](https://filab.fr/wp-content/themes/astra-child/templates/assets/img/stars.svg)](https://www.avis-verifies.com/avis-clients/filab.fr)
## Laboratory specializing in analysis and expertise for industrial companies

 ![More than 140 people](https://filab.fr/wp-content/uploads/2024/10/collaborateurs-1.svg) More than 140 people at your service ![5200 m² laboratory](https://filab.fr/wp-content/uploads/2024/10/labo.svg) 5200 m² laboratory + 99% of services are provided in-house ![Accredited laboratory](https://filab.fr/wp-content/uploads/2024/10/ISO-17025-1.svg) Accredited laboratory COFRAC ISO 17025 ![+2200 clients](https://filab.fr/wp-content/uploads/2024/10/clients.svg) +2200 clients in France and abroad
### Contact us

 Our services are reserved for professionals.  [![phone](https://filab.fr/wp-content/themes/astra-child/templates/assets/img/form/phone.svg) Call
 us +33 (0)3 80 52 32 05](tel:+33380523205) [![location](https://filab.fr/wp-content/themes/astra-child/templates/assets/img/form/location.svg) Visit us 80 rue Jean-Louis Auguste Petitjean
 21850 - Saint Apollinaire - FRANCE](https://www.google.com/maps/place/Filab/@47.317329,5.076545,15z/data=!4m6!3m5!1s0x47f29e6ab37d6a1d:0xa2cc1016c4f74422!8m2!3d47.317793!4d5.0767354!16s%2Fg%2F1v3gr7f0?entry=ttu) [![mail](https://filab.fr/wp-content/themes/astra-child/templates/assets/img/form/envelope.svg) Contact
 us contact@filab.fr](mailto:contact@filab.fr?subject=%5BVotre%20demande%20:%20How%20did%20FILAB%20help%20one%20of%20its%20clients%20determine%20the%20cause%20of%20steel%20piston%20failure%20(at%20the%20rod)?%20-%20Case%20study%20en%20%5D) For complaints: all complaints must be sent by mail to contact@filab.fr or by contacting the person who signed the report. The complaint handling procedure is available upon request. In the event of a complaint concerning the laboratory's activities, the customer may be notified of the complaint's handling.