type: "WebPage"
title: "MIL-P-83348 Testing"
description: "Do you need to validate the compliance of your thermal spray powders according to MIL-P-83348? Securing surface coating performance with MIL-P-83348 requirement In the Aerospace, Space, and Defense (ASD) sectors, thermal spray coatings (plasma, HVOF) are essential for protecting components..."
resource: "https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/mil-p-83348-analysis/"
tags: ["EN", "pll_698edf14dab50", "Arnaud JOUDRAIN Meta"]
timestamp: "2026-02-18T16:20:56Z"
published: "2026-02-13T08:30:27Z"
language: "en"
author: "Filab"
---

# MIL-P-83348 Testing

## Do you need to validate the compliance of your thermal spray powders according to MIL-P-83348?

### Securing surface coating performance with MIL-P-83348 requirement

In the [Aerospace](https://filab.fr/en/sectors-of-activity/laboratory-analysis-aeronautics-aerospace.md), [Space](https://filab.fr/en/sectors-of-activity/laboratory-analysis-aeronautics-aerospace.md), and [Defense](https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector.md) (ASD) sectors, thermal spray coatings (plasma, HVOF) are essential for protecting components against [wear](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-failures/laboratory-analysis-wear.md), heat, and[corrosion](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-deposit-contamination/laboratory-expertise-and-analysis-of-corrosion.md). The quality of the final [coating](https://filab.fr/en/our-services/our-expertise-services/electrochemical-characterization/anticorrosive-coating-analysis.md) depends directly on the intrinsic properties of the [powder](https://filab.fr/en/our-services/our-analysis-services/laboratory-analysis-powder-characterization.md). Any deviation can impact the durability of your **essential parts.**

The **MIL-P-83348** military specification defines requirements for [metal powders](https://filab.fr/en/our-services/our-analysis-services/laboratory-analysis-powder-characterization/metallic-powders-characterization-services-at-filab-laboratory.md) ([Nickel](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/laboratory-analysis-nickel-alloys.md), [Cobalt](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/laboratory-analysis-cobalt-alloys.md), [Chrome](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/laboratory-analysis-chromium.md) alloys, etc.) used for protective coatings. It imposes strict controls on[chemical composition](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/metallic-alloy-analysis-laboratory.md), [particle size distribution](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-particulate-contaminant/laboratory-for-particle-size-distribution-analysis-according-to-iso-17025.md), and particle [morphology](https://filab.fr/en/laboratory-analysis-powder-morphology.md) to guarantee optimal melting during spraying.

At **FILAB**, we support applicators and powder manufacturers in the ASD supply chain with the qualification of their materials according to MIL-P-83348, with a clear goal: to ensure the reliability of your technical and industrial decisions.

### MIL-P-83348: a flowability and purity challenge

### Thermal spray powder compliance control according to MIL-P-83348

Compliance with this requirement guarantees that the powder will behave predictably in the spray torch and that the deposit will exhibit the expected hardness and adhesion characteristics.

It is specifically used to:

- **Verify chemical composition** by ICP-OES to guarantee alloying element content and limit impurities.
- **Analyze particle size** (often by laser diffraction or sieving) to ensure the size is adapted to the spraying process.
- **Characterize grain morphology** (sphericity, internal porosity) which directly influences final coating density.

 

In the Aerospace and Defense industries, compliance with MIL-P-83348 has a direct impact on:

- **Thermal resistance** of thermal barrier coatings (TBC) in engines.
- **Wear protection of landing gear** and transmission shafts.
- **Interface quality** between the substrate and the coating to avoid spalling.

## FILAB, a laboratory tailored to aerospace & defense requirements

### An analytical park dedicated to MIL-P-83348 expertise

Characterizing thermal spray powders requires instrumentation capable of linking chemistry and particle physics. To meet the requirements of MIL-P-83348, **FILAB** provides its clients with state-of-the-art tools:

  [### ICP-OES

for comprehensive chemical analysis, including trace metals](https://filab.fr/en/our-technical-resources/laboratory-analysis-icp-icp-ms-icp-aes.md) [### SEM-EDX

for morphological analysis and detection of particulate contamination](https://filab.fr/en/our-technical-resources/laboratory-analysis-sem-scanning-electron-microscopy.md) [### Laser diffraction analysis](https://filab.fr/en/our-technical-resources/laboratory-analysis-laser-granulometry.md) [### Sieving

for the control of particle size fractions](https://filab.fr/en/our-technical-resources/sieve-analysis-laboratory.md)
### Density and flowability measurement

(Hall Flowmeter) to anticipate machine behavior

### PSD

 [### Pycnometry](https://filab.fr/en/our-technical-resources/helium-pycnometry-analysis-laboratory.md)
### Dedicated material expertise services

At **FILAB**, analyses according to MIL-P-83348 are part of a global approach to surface process control. Our teams work on:

Systematic receiving inspection on powder batches before spraying

[Recycling monitoring](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/metallic-powders-characterization-services-at-filab-laboratory/study-of-the-recycling-of-metal-powders-in-the-laboratory.md) to evaluate degradation (oxidation)

Coating defect expertise (excessive [porosity](https://filab.fr/en/our-services/our-analysis-services/polymer-materials-analysis-laboratory/laboratory-material-testing/porosity-porosimetry-analysis/), [inclusions](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-failures/inclusion-analysis-on-laboratory-materials.md), poor adhesion)

### Why choose FILAB?

- **45 years** of recognized expertise in analysis and materials science
- **Dual competence:** Chemistry / Materials
- Specializing in **metallic alloys**and **critical applications**
- **Customer qualification**: Safran, Dassault Aviation, and Framatome
- **ISO 17025 Accreditation** regarding metallic alloys

  [Discover our accreditations](https://filab.fr/en/about-us/accreditations-en.md)  Discover our metallurgical expertise
## Analysis of Iron, Aluminium, Molybdenum, Copper, Tin, Chromium, Titanium, Lead, Nickel, Zinc

 [Learn more](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory.md)
### Our analytical services in accordance with MIL requirements for the ASD sector

[Analysis according to MIL-A-22771 requirement](https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/mil-a-22771-analysis.md)

[Analysis according to MIL-S-22499 requirement](https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/mil-s-22499-analysis.md)

[Analysis according to MIL-T-9047 requirement](https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/mil-t-9047-analysis.md)

[Analysis according to MIL-A-6088 requirement](https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/mil-a-6088-analysis.md)

[Analysis according to MIL-DTL-14067 requirement](https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/mil-dtl-14067-analysis.md)

[Analysis according to MIL-DTL-5002 requirement](https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/mil-dtl-5002-analysis.md)

### Our analytical services based on ISO and ASTM standards for the ASD sector

[Analysis according to ASTM E3061 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-e3061.md)

[Analysis according to ASTM E1086 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-e1086.md)

[Analysis according to ASTM E1019 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-e1019.md)

[Analysis according to ISO 8287 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/iso-8287-testing.md)

[Analysis according to ASTM B213 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/analysis-astm-b213.md)

[Analysis according to ASTM B964 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-b964.md)

[Analysis according to ISO 12154 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-iso-12154.md)

[Analysis according to ASTM E1868 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-e1868.md)

[Analysis according to ASTM E1409 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-e1409-analysis.md)

[Analysis according to ASTM E415 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-e415.md)

[Analysis according to ASTM E1251 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-e1086.md)

[Analysis according to ISO 15350 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/iso-15350-testing.md)

[Analysis according to ISO 4935 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/iso-4935-analysis.md)

[Analysis according to ISO 4490 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/iso-4490-analysis.md)

[Analysis according to ASTM B527 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-b527.md)

[Analysis according to ASTM B923 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-b923.md)

[Analysis according to ASTM A269 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/astm-analysis-a269.md)

[Analysis according to ASTM E1941 standard](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/analysis-astm-e1941.md)

### Our additional metallographic analysis

[Micrographic analysis](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/laboratory-micrographic-examination.md)

[Failure analysis](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-failures.md)

[Chemical composition analysis](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/metallic-alloy-analysis-laboratory.md)

[Metallurgical analysis](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory.md)

[Metallographic analysis](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/examination-metallographic-section-laboratory.md)

[Elemental analysis](https://filab.fr/en/our-services/our-analysis-services/chemical-analysis-laboratory/laboratory-elemental-analysis.md)

[Analysis of metallic alloys](https://filab.fr/en/analysis-of-metallic-alloys-in-the-laboratory.md)

## Our FAQ

 What types of alloys are commonly tested under MIL-P-83348?
We mainly find **Nickel-based** powders (Nickel Aluminides), **Cobalt-based** (Stellite), or **MCrAlY alloys** used as **bond coats** for thermal barriers.

 Why is particle size so precise in this requirement?
If particles are too fine, they evaporate or overheat in the plasma jet. If they are too coarse, they do not melt completely, creating **"unmelted particles"** (or unmelts) in the coating which weaken its properties.

 Can FILAB measure oxygen in these powders?
Yes, Oxygen and Nitrogen determination is crucial because an overly oxidized powder loses its adhesion capabilities. We use **Inert Gas Fusion (ONH)** for these measurements.

 Can you analyze the final coating in addition to the powder?
Absolutely. FILAB can perform **micrographic cross-sections** on your test coupons to verify porosity, thickness, and structure of the deposit according to your complementary specifications.

 How to get a quote?