type: "WebPage"
title: "Surface treatment failure on an optronic component embedded in the laboratory"
description: "Sécuriser la performance des composants optroniques grâce à l’analyse des traitements de surface The onboard optoelectronic components (sights, sensors, cameras, guidance systems) must operate reliably in harsh environments : thermal fluctuations, vibrations, corrosive atmospheres, and exposure to dust or sand.Surface..."
resource: "https://filab.fr/en/sectors-of-activity/laboratory-analyses-tests-defense-security-sector/surface-treatment-failure-optronic-component-embedded-laborator/"
tags: ["EN", "pll_694a9318a4325", "Arnaud JOUDRAIN"]
timestamp: "2026-07-09T14:04:36Z"
published: "2025-12-23T13:13:32Z"
language: "en"
author: "Théa Quilliou"
---

# Surface treatment failure on an optronic component embedded in the laboratory

## Sécuriser la performance des composants optroniques grâce à l’analyse des traitements de surface

The onboard optoelectronic components (sights, sensors, cameras, guidance systems) must operate reliably in **harsh environments** : thermal fluctuations, vibrations, corrosive atmospheres, and exposure to dust or sand.

Surface treatments ([anodizing](https://filab.fr/en/our-services/our-analysis-services/laboratory-surface-characterization/analysis-of-a-surface-treatment-by-anodizing.md), [passivation](https://filab.fr/en/our-services/our-analysis-services/laboratory-surface-characterization/laboratory-characterization-passivation.md), [coatings](https://filab.fr/en/our-services/our-analysis-services/laboratory-surface-characterization/laboratory-surface-coating-characterization.md)) are essential to protect components, ensure their **durability** and **maintain optical and mechanical performance.**

A failure of [surface treatment](https://filab.fr/en/our-services/our-analysis-services/laboratory-surface-characterization/laboratory-analysis-expertise-surface-treatment.md) can cause corrosion, optical drift, loss of adhesion, or deterioration of mechanical properties.

 L’expertise matériaux devient alors un levier stratégique pour identifier la cause racine et éviter la récurrence.
## Contexte et contraintes spécifiques aux composants optroniques

Embedded optronic components are subject to specific constraints:

- Severe environmental stresses: humidity, temperature, dust, sand
- Vibrations and shocks during operation or testing
- Critical interfaces: metal \/ coating \/ bonding
- Minimal tolerance for surface defects or contamination
- Strict standards requirements (ASTM, [MIL-STD](https://filab.fr/secteur-activite/analyse-microelectronique-analyse-defense-securite/tests-mil-std-analysis-laboratoire/), ISO, RCTA DO)

### Analyse et expertise

 FILAB accompagne les industriels de l’optronique à chaque étape : Expertise défaillance traitements de surface
- Analysis of treatment defects (anodizing, passivation, coatings)
- Identification of [corrosion](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-deposit-contamination/laboratory-expertise-and-analysis-of-corrosion.md), cracking or loss of adhesion
- Diagnosis after severe environmental testing
- [Surface treatment bath analysis](https://filab.fr/nos-prestations/analyse/laboratoire-caracterisation-des-materiaux/analyse-bain-traitement-surface/)

 Analyse de surface et pollution
- Characterization of critical surface conditions
- Detection of contamination that could compromise treatment effectiveness
- Verification of protective treatments

 Contrôle non destructif
- analysis without damaging optronic components
- Expertise on complex embedded systems
- Support for confidential and secure interventions

## Nos techniques dédiées à l'expertise matériaux

 [### ICP-MS, ICP-AES, ICP-MS/MS](https://filab.fr/en/our-technical-resources/laboratory-analysis-icp-icp-ms-icp-aes.md) [### Elemental analyzers

C, H, N, S, O](https://filab.fr/en/our-technical-resources/chons-laboratory-analysis.md) [### Analyse de surface : AFM, XPS, TOF-SIMS](https://filab.fr/nos-moyens-techniques/laboratoire-analyse-afm.md) [### MEB-EDX, MEB-FEG, MEB-EBSD](https://filab.fr/en/our-technical-resources/laboratory-analysis-sem-scanning-electron-microscopy.md) [### ATG](https://filab.fr/en/our-technical-resources/tga-tga-ftir-and-tga-ms-analysis-at-filab-laboratory.md) [### DSC](https://filab.fr/en/our-technical-resources/laboratory-analysis-dsc-calorimetric.md) [### DRX](https://filab.fr/en/our-technical-resources/x-ray-crystallography-laboratory-xrd.md) [### Py-GC-MS](https://filab.fr/en/our-technical-resources/py-gc-ms-pyrolysis-gc-ms.md) [### Tomographie x](https://filab.fr/en/our-technical-resources/tomography-analysis-laboratory.md) [### Optical microscope](https://filab.fr/en/our-technical-resources/laboratory-of-analysis-and-observation-by-optical-microscope-mo.md)
### Why choose FILAB?

- **45 years of expertise** in materials analysis and expertise
- **Dual expertise** in chemistry \/ materials
- An approach focused on understanding root causes
- **Approved by Safran, Dassault Aviation and Framatome**

## FAQ

 Quels traitements de surface peuvent être analysés ?
- Anodizing,
- passivation,
- metallic or organic coatings,
- protective layers.

 Peut-on analyser un composant sans le détruire ?
Yes. FILAB favors non-destructive testing methods suited to sensitive components.

 Quels défauts peuvent être détectés ?
- Corrosion,
- Cracking,
- Loss of adhesion,
- Continuity defects or surface contamination.

 Travaillez-vous selon les normes défense et aéronautiques ?
Yes. The analysis are carried out according to the standards **ASTM, MIL-STD, IPC, ISO, RCTA DO**, depending on the program requirements.

 I need to speak with a technical expert, how do I do that?
To speak with a technical expert, we invite you to fill out the **contact form** on the right, specifying your **need**, or by calling us directly at **03 80 52 32 05**.

An expert will call you back to discuss your needs in more depth and provide you with a quote tailored to your analytical requirements.

 How long does it take to get a quote from the FILAB laboratory?
Generally, you receive your quote within **24-48 hours.**