# ICP analysis laboratory for medical devices

**Did you know** **?** FILAB was the first laboratory in France accredited by COFRAC ISO 17025 for [the analysis of HCT and TOC cleaning residues](https://filab.fr/en/our-services/our-expertise-services/laboratory-analyis-standard-iso-19227/hct-toc-analysis-cleaning-process-validation-for-medical-devices.md) as well as for [inorganic residues by ICP in accordance with ISO 19227](https://filab.fr/en/our-services/our-expertise-services/laboratory-analyis-standard-iso-19227.md) for Medical Devices.

## Our ICP analysis services

FILAB’s laboratory has around fifteen [ICP](https://filab.fr/en/our-technical-resources/laboratory-analysis-icp-icp-ms-icp-aes.md) techniques, including [one ICP-MS/MS](https://www.thermofisher.com/fr/fr/home/industrial/mass-spectrometry/inductively-coupled-plasma-mass-spectrometry-icp-ms.html?ce=E.21CMD.DL107.39849.01&cid=E.21CMD.DL107.39849.01&ef_id=Cj0KCQjwsZKJBhC0ARIsAJ96n3XHjFRU7A3uvF5h6O0PAx5a2SQz1GX6FVqZXW-AAS_SnOEIQOSYKyQaAjr1EALw_wcB:G:s&s_kwcid=AL!3652!3!248651463792!p!!g!!thermo%20icp%20ms) within its [analytical equipment portfolio](https://filab.fr/en/our-technical-resources.md). This chemical analysis technique enables us to provide the following services to [medical device](https://filab.fr/en/sectors-of-activity/laboratory-analysis-medical-devices.md) manufacturers:

 ![ICP-AES](https://filab.fr/wp-content/uploads/elementor/thumbs/analyse-ICP-dispositifs-medicaux-1-pvpgjz1rmvwogthfo5ohhurmpmqp3jnpfy5rhjufpo.jpg)
## Our Services

Elemental residue testing in accordance with [ISO 19227](https://filab.fr/en/our-services/our-expertise-services/laboratory-analyis-standard-iso-19227.md) 

Biocompatibility study according to [ISO 10993](https://filab.fr/en/our-services/our-expertise-services/laboratory-biocompatibility-testing.md) ( -[18](https://filab.fr/en/our-services/our-expertise-services/laboratory-biocompatibility-testing/laboratory-material-chemical-characterization.md) / -[12](https://filab.fr/en/our-services/our-expertise-services/laboratory-biocompatibility-testing/laboratory-exhaustiveness-verification-iso-10993-12.md) / -[13](https://filab.fr/en/our-services/our-expertise-services/laboratory-biocompatibility-testing/iso-10993-13-medical-devices-characterization.md) / -[14](https://filab.fr/en/our-services/our-expertise-services/laboratory-biocompatibility-testing/identification-and-quantification-of-degradation-products-on-ceramic-medical-devices-according-to-iso-10993-14.md) / -15 / -19 / -[22](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-nanomaterial/laboratoty-iso-10993-22-nanomaterial-characterization.md) )

[R&D support](https://filab.fr/en/our-services/rd.md): tailor-made [chemical analysis](https://filab.fr/en/our-services/our-analysis-services/laboratory-analysis-nitrosamines/laboratory-analysis-biomedicine.md), [material and surface characterization](https://filab.fr/en/our-services/our-analysis-services/laboratory-material-testing.md), [analytical development](https://filab.fr/en/our-services/our-expertise-services/analytical-development.md)

Analysis of inorganic residues in polymers [in accordance with ISO 10993-18](https://filab.fr/en/our-services/our-expertise-services/laboratory-biocompatibility-testing/laboratory-material-chemical-characterization.md) or extractables and leachables studies

[Problem solving](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-failures.md): non-conformity, [failure](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-failures/laboratory-analysis-ruptures.md), [adhesion](https://filab.fr/paroles-d-expert/metallurgie-fonderie-automobile/filab-vous-accompagne-dans-les-problematiques-d-adhesion.md), [corrosion](https://filab.fr/en/our-services/our-expertise-services/laboratory-analysis-deposit-contamination/laboratory-expertise-and-analysis-of-corrosion.md)...

Process validation: [Cleaning](https://filab.fr/en/our-services/our-expertise-services/laboratory-analyis-standard-iso-19227.md) (ISO 19227), [surface treatment](https://filab.fr/en/our-services/our-analysis-services/laboratory-surface-characterization/laboratory-analysis-expertise-surface-treatment.md)