type: "WebPage"
title: "RCC-M S8300 analysis laboratory"
description: "Do you want to secure the compliance of your nuclear materials and equipment? In the Nuclear sector, mastering regulatory requirements is an absolute must. The RCC-M, and more specifically paragraph S8300, defines the requirements relating to chemical analysis of metal..."
resource: "https://filab.fr/en/sectors-of-activity/laboratory-analysis-nuclear-energy/rccm-s8300-analysis/"
tags: ["EN", "pll_6954e765d2050", "Clément BOENARD"]
timestamp: "2026-07-08T08:12:00Z"
published: "2025-12-31T09:32:15Z"
language: "en"
author: "Laure Durieux"
---

# RCC-M S8300 analysis laboratory

## Do you want to secure the compliance of your nuclear materials and equipment?

In the [Nuclear sector](https://filab.fr/en/sectors-of-activity/laboratory-analysis-nuclear-energy.md), mastering regulatory requirements is an absolute must. The [RCC-M](https://filab.fr/en/our-services/our-analysis-services/halogen-analysis-laboratory/halogen-analysis-rcc-m.md), and more specifically paragraph **S8300**, defines the requirements relating to **[chemical analysis](https://filab.fr/nos-prestations/analyse/analysis-chimiques/) of [metal materials](https://filab.fr/nos-prestations/analyse/laboratoire-caracterisation-des-materiaux/laboratoire-expertise-materiau-metallique.md)** used in the manufacture of nuclear pressure equipment.

At Filab laboratory, we support nuclear industry players in the **performance of chemical analysis compliant with RCC-M S8300**, providing reliable, interpretable results that can be used in your regulatory files.

### What is RCC-M S8300?

The **[RCC-M](https://www.afcen.com/fr/rcc-m/194-rcc-m.html) (Design and Construction Rules for Mechanical Components of PWR Nuclear Islands)** governs compliance with the materials used in nuclear equipment.

Chapter **S8300** specifies:

- The **chemical analysis methods** to be implemented
- The **elements to be measured** (major elements, minor elements, impurities)
- The **requirements for traceability, accuracy, and reproducibility**
- The conditions for **qualifying analytical results**

### Our RCC-M S8300 analysis services

We carry out **complete and targeted chemical analysis**, strictly aligned with the requirements of RCC-M S8300, across a wide range of metal materials.

#### The materials concerned

Carbon and low-alloy steels

[Nickel alloys](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/laboratory-analysis-nickel-alloys.md)

[Austenitic, ferritic and martensitic stainless steels](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/stainless-steel-analysis-iso-3651-1.md)

[Nuclear-specific alloys](https://filab.fr/en/our-services/our-analysis-services/metallurgical-analysis-laboratory/analysis-of-metallic-alloys-for-the-energy-and-nuclear-industry.md)

#### The elements analyzed

Major elements: C, Mn, Si, Cr, Ni, Mo, etc.

Critical impurities (S, P, O, N, H depending on requirements)

Alloying and residual elements

### Our technical resources for RCC-M S8300 analysis

  [### ICP-OES / ICP-MS](https://filab.fr/en/our-technical-resources/laboratory-analysis-icp-icp-ms-icp-aes.md) [### Elemental analyzer](https://filab.fr/en/our-technical-resources/chons-laboratory-analysis.md) [### Optical emission spectrometry (OES)](https://filab.fr/en/our-technical-resources/laboratory-analysis-oes-alloys.md)
## The FILAB laboratory supports you with RCC-M S8300 analysis

### Why carry out an RCC-M S8300 analysis?

Our expertise is particularly sought in the event of:

- Doubt about material compliance
- Analytical discrepancy between suppliers
- Requalification of equipment in service
- Investigations following an anomaly or process drift

### Why choose FILAB for an RCC-M S8300 analysis?

- Results that can be used in your RCC-M files****
- Expert interpretation
  in line with regulatory thresholds****
- ****

### Our RCC-M analysis services

[Halogen analysis according to RCC-M](https://filab.fr/en/our-services/our-analysis-services/halogen-analysis-laboratory/halogen-analysis-rcc-m.md)

[Water analysis according to RCCM](https://filab.fr/secteur-activite/analyse-energie-analyse-nucleaire/laboratoire-analysis-eaux-rccm/)

[Chemical analysis according to RCC-M](https://filab.fr/secteur-activite/analyse-energie-analyse-nucleaire/analysis-chimiques-rccm/)

[Metallurgical analysis according to RCC-M](https://filab.fr/nos-prestations/analyse/laboratoire-analysis-metallurgiques/analysis-metallurgiques-rccm/)

## FAQ

 Is RCC-M S8300 mandatory for nuclear equipment?
Yes. RCC-M is the reference standard for the design and manufacture of mechanical equipment for PWR nuclear islands. Section S8300 is essential to demonstrate the **chemical compliance of the metallic materials** used, particularly in pressure equipment.

 What types of chemical analysis are required by RCC-M S8300?
S8300 requires **quantitative chemical analysis** to verify the exact composition of the materials:

- major and alloying elements,
- residual elements,
- critical impurities (sulfur, phosphorus, carbon, nitrogen, oxygen, hydrogen depending on the case).

The analytical methods must be **appropriate, justified and traceable**.

 Which materials does RCC-M S8300 apply to?
RCC-M S8300 mainly applies to:

- carbon and low-alloy steels,
- stainless steels,
- nickel alloys,
- specific metallic materials used in nuclear applications.

 Are the results usable in an RCC-M regulatory file?
Yes. The analysis carried out at filab are **documented, traceable and compliant with RCC-M requirements**, so they can be integrated into your technical, manufacturing or regulatory justification files.

 Do you need an analysis according to RCC-M S8300?
Whether for material qualification, supplier acceptance or a technical investigation, our teams support you with a high level of rigor and reliability.