Analytical laboratory according to ASTM E2465 standard

Chemical analysis Characterization of materials Problem solving
More than 140 people
More than 140 people at your service
5200 m² laboratory
5200 m² laboratory + 99% of services are provided in-house
Accredited laboratory
Accredited laboratory COFRAC ISO 17025

X-ray fluorescence analysis: Your partner for analyses according to ASTM E2465

Need to validate the conformity of your products according to ASTM E2465?

Ensuring the conformity of your iron and nickel alloys is a fundamental lever for guaranteeing the safety of your components and accelerating your time to market.

To meet traceability requirements, the FILAB laboratory supports you in securing your supply chains through expert analysis according to ASTM E2465 using X-ray fluorescence spectrometry (XRF).

Understanding the issues and requirements of the ASTM E2465 standard

This standard defines the chemical analysis methods for determining the elemental composition of stainless steels and nickel alloys. It is essential for validating the metallurgical quality and corrosion resistance of your industrial materials.

FILAB laboratory expertise: a comprehensive approach to chemistry and materials

A 5200 m² analytical facility at your service

To meet the precision requirements of ASTM E2465, the FILAB laboratory has a state-of-the-art infrastructure for detailed chemical characterization of your samples:

  • X-ray Fluorescence Spectrometry (XRF) for direct elemental analysis.
  • Inductively Coupled Plasma Exploration (ICP-AES) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for trace and ultratrace analysis.
  • Scanning Electron Microscopy (SEM-EDX) for surface and fracture surface analysis.
  • X-ray Diffraction (XRD) for crystalline phase identification.

Related services for comprehensive expertise

To provide a 360° view of your materials, we offer complementary services within our departments:

Why choose the FILAB laboratory for your analysis?

Partnering with FILAB means transforming your analytical needs into strategic decision-making tools:

  • Recognized expertise: 45 years of expertise in fine chemicals and advanced metallurgy.
  • Guaranteed reliability: ISO 17025 accreditation by COFRAC (scope available at www.cofrac.fr).
  • Industry recognition: Trusted partner of major contractors (Safran, Dassault Aviation, Framatome, EDF, etc.).
  • Expert profiles: A team of 140 employees, primarily PhDs and engineers.
  • CSR commitment: EcoVadis Award, guaranteeing responsible practices.

Our FAQ

What is the ASTM E2465 standard?

ASTM E2465 is a standardized test method for the analysis of stainless steels and alloys with high nickel, cobalt, and iron content. It uses wavelength-dispersive X-ray fluorescence (XRF) spectrometry to determine the precise chemical composition of the materials.

What types of metals are covered by this analysis?

This standard is specifically designed for complex alloys, including:

  • Stainless steels (300, 400 series, etc.).
  • Nickel-based superalloys (Inconel, Hastelloy).
  • Cobalt-based alloys (Stellite).
  • Ferrous alloys with high chromium or molybdenum content.
Why choose XRF technology for the ASTM E2465 standard?

X-ray fluorescence (XRF) spectroscopy is preferred because it offers:

  • High precision for major elements (chromium, nickel, molybdenum).
  • Non-destructive analysis (or minimally destructive analysis depending on sample preparation).
  • Faster execution speed compared to traditional wet chemistry methods.
What chemical elements were measured?

The laboratory typically quantifies the following elements:

  • Primary elements: Iron (Fe), Chromium (Cr), Nickel (Ni), Cobalt (Co).
  • Alloying elements: Molybdenum (Mo), Copper (Cu), Manganese (Mn), Silicon (Si), Tungsten (W), Niobium (Nb).
How to get a quote from FILAB?

To obtain a quote, you can contact our team via our contact form, by phone, or by email.

Simply tell us your requirements (type of material, desired analysis, applicable standards, urgency, quantity of samples, etc.). We will then send you a personalized technical and pricing proposal within 24-48 hours.

What is the typical duration of the analysis?

Turnaround times vary depending on the nature of the analysis and the complexity of the expert assessment project.

However, FILAB is committed to providing fast turnaround times tailored to your industrial constraints and urgent needs.

The filab advantages
A highly qualified team
A highly qualified team
Responsiveness in responding to and processing requests
Responsiveness in responding to and processing requests
A COFRAC ISO 17025 accredited laboratory
A COFRAC ISO 17025 accredited laboratory
(Staves available on www.cofrac.com - Accreditation number: 1-1793)
A complete analytical facility of 5,200m²
A complete analytical facility of 5,200m²
Tailor-made support
Tailor-made support
Video debriefing available with the expert
Video debriefing available with the expert
Anaïs DECAUX Customer Support Manager
Ask for your quote