Case study

Determination of chromium oxidation states by XPS

Our client suspected the presence of chromium VI on a part coated with yellow zinc.
Accueil Blog Determination of chromium oxidation states by XPS

How FILAB helped one of its clients determine the different oxidation states of chromium using XPS in a powder?

Chromium is a chemical element belonging to the transition metals group. It is a hard, shiny, corrosion-resistant metal used in many fields due to its physical and chemical properties. Chromium has different oxidation levels.

During the manufacture of industrial parts for the aerospace industry, our client suspected the presence of chromium VI on a part coated with yellow zinc. After initial internal investigations, FILAB was asked to determine the presence of chromium VI on this coating and to quantify it.

Summary

01
Determination of the presence of Chromium VI by XPS
02
Abrasion was necessary to determine the presence or absence of chromium VI.
03
Deconvolution of the Cr2p peak allows the degree of chromium oxidation to be identified.
04
Why FILAB?
01

Determination of the presence of Chromium VI by XPS

In order to carry out this study, the technique used is X-ray Photoelectron Spectroscopy (XPS), which allows for elemental, structural, and quantitative analysis of the extreme surface (a few nm deep) of a sample.

XPS is a quantitative chemical analysis technique with a depth of investigation in the nanometer range (typically between 2 and 4 nm). It can be applied to all solid samples that can withstand ultra-high vacuum (working pressure in the order of 10-8 Pa). It is therefore used in the case of the metal part that our customer wishes to have analyzed.
The sample is subjected to X-rays (generally Kα line of aluminum or magnesium). The X-rays excite the elements present in the sample. The result of the excitation can be the direct emission of an electron from a particular level (photoionization). XPS analysis consists of filtering by energy (using the analyzer) and detecting these photoelectrons.

02

Abrasion was necessary to determine the presence or absence of chromium VI.

The initial analysis did not identify the presence of chromium in the sample due to the large amount of carbon on the sample's surface. We therefore abraded the sample's surface by 2-3 nanometers to remove this contamination.

XPS spectra of the sample – before abrasion (in green) and after abrasion (in red)

03

Deconvolution of the Cr2p peak allows the degree of chromium oxidation to be identified.

The energies of these contributions correspond to an oxidation state of +III. Indeed, the energies of the contributions linked to the oxidation state of +VI are located around 580 eV for the 2p3/2 peak and 589 eV for the 2p1/2 peak. These contributions are not present in the high-resolution spectrum of Chromium Cr2p.

High-resolution XPS spectra of Cr2p chromium from sample 2302-E0130013 after abrasion

The outer surface of the coated part therefore only contains trivalent chromium Cr (III). No traces of hexavalent chromium Cr (VI) were identified.

04

Why FILAB?

With significant experience in implementing Chrome VI analysis techniques, the FILAB laboratory can assist you with your needs:

  • Chemical composition analysis and Chrome 6 (Chrome VI) testing
  • Chromium 6 (chromium VI) testing on a glass sample
  • Chromium 6 (chromium VI) testing on a part that has undergone nitrochromic treatment
  • Determining the residual chromium 6 (chromium VI) content of surface treatments
  • Chromium 6 (chromium VI) analysis on powder using UV spectrometry
Need help? Contact our team

Other studies that may be of interest to you

Corrosion rate: the strategic choice of materials

One of our customers wanted to test the corrosion resistance of their heat exchangers. Find out more

Yellowing of silicone

Silicones are now widely used in various fields thanks to their remarkable physical and chemical properties, such as excellent thermal stability, high resistance to oxidation and hydrolysis, and excellent gas permeability. Find out more

Galvanic coupling: securing a naval assembly

One of our customers encountered sealing issues during the final validation tests of their product. Find out more

Services associated with the case study

Analysis of a chromium oxide protective layer

Support in solving oxidation problems of materials and products

Laboratory analysis and expertise of Chrome and its alloys

Laboratory expertise and analysis of corrosion

Laboratory specializing in analysis and expertise for industrial companies

More than 140 people
More than 140 people at your service
5200 m² laboratory
5200 m² laboratory + 99% of services are provided in-house
Accredited laboratory
Accredited laboratory COFRAC ISO 17025
+2200 clients
+2200 clients in France and abroad

Contact us

Our services are reserved for professionals.