Extractables and Leachables Testing Laboratory according to USP 1664

Chemical analysis Problem solving
More than 140 people
More than 140 people at your service
5200 m² laboratory
5200 m² laboratory + 99% of services are provided in-house
Accredited laboratory
Accredited laboratory COFRAC ISO 17025

The chapter USP <1664> “Assessment of Drug Product Leachables Associated with Pharmaceutical Packaging/Delivery Systems” is an informational chapter of the United States Pharmacopeia (USP). It applies to the evaluation of leachables in the finished pharmaceutical product

As a pharmaceutical manufacturer, you want to carry out an extractables analysis according to USP 1664

What does USP 1664 say?

USP 1664 is a guideline from the United States Pharmacopeia (USP) focused on assessing the leaching risks of packaging materials in contact with pharmaceutical products.

USP 1664

This section focuses on the identification and quantification of leachable compounds (leachables), which are the chemical entities that actually migrate from packaging or delivery systems into the finished pharmaceutical product under its real storage conditions. Unlike extractables obtained under forced conditions, the study according to USP <1664> establishes rigorous protocols for analyzing substances in direct contact with the formulation, as well as migrants crossing the physical barriers of secondary packaging.

Why carry out a study according to USP 1664?

The main objective is to characterize the leachables profile in order to assess risks to patient safety, based on strict toxicity thresholds such as the SCT (Safety Concern Threshold) and the QT (Qualification Threshold). This approach not only helps ensure the drug’s stability, but also establishes a qualitative and quantitative correlation with the extractables studies (USP <1663>) previously carried out.

The FILAB laboratory supports pharmaceutical manufacturers in leachables analysis according to USP 1664

Study strategies: real study or simulation?

Depending on the complexity of your formulation matrix, FILAB supports you with two approaches defined by USP 1664:

  • The formal leachables study: carried out on the actual product, in its final commercial packaging, including real-time testing (stability).
 
  • The simulation study: a core concept of USP 1664, it makes it possible to replace the complex matrix of the finished product with a simulating solvent (surrogate) with the same extraction power. This approach is recommended when direct analysis is not feasible due to very low thresholds or major interferences.

Our analytical techniques for extractables according to USP 1664

GC-MS

LC-HRMS, LC-Orbitrap

LC-HRMS, LC-QTOF

ICP-MS, ICP-MS/MS & ICP-AES

SEM-EDX

  • the GC-MS, HPLC or UHPLC/MS/MS for the search, identification and quantification of organic compounds present in solvents, UV stabilizers, antioxidants, colorants, inks, detergent residues, sterilization residues, polymer residues… that have been extracted and/or leached from the material by a standardized simulant
  • the ICP-AES and ICP-MS particularly suited to mineral or metallic contaminants or additives, such as heavy metals, mineral or metallic fillers, colorants…
  • microscopy SEM-EDX, a true rapid and versatile diagnostic tool for assessing the material surface condition after aging, observing particles, deposits…

Why choose FILAB for your USP 1664 analyses?

  • COFRAC ISO 17025 accreditation and GMP environment
    Guarantees technical competence, the traceability of our measurements, and the enforceability of our analytical results with French, European, and U.S. FDA regulatory authorities.
  • Comprehensive multi-technique analytical platform
  • Mastery of regulatory thresholds (AET, SCT…)
  • Structured reports for your regulatory submissions
    Each FILAB report is structured for direct integration into your files: Module 3 CTD, IMPD, STED, BER, 510(k) or PMA dossier. Our deliverables include detailed operating conditions, annotated chromatograms, identification/quantification tables, and toxicological assessment of the detected compounds.

Let's discuss your project

Do you need extractables & leachables studies? 

👉 Contact our teams to discuss your project.

Did you know?

The FILAB laboratory has been COFRAC ISO 17025 accredited for the following scope since 2015: Analysis and quantification of elemental impurities and minerals, including heavy metals, by ICP-AES and ICP-MS in cosmetic and pharmaceutical products according to European Pharmacopoeia 2.4.20 and USP 233

Our FAQ

Can a USP 1664 study be carried out without a prior USP 1663 study?

Ideally, no. USP 1663 provides the list of target compounds. Without this profile, it is difficult to demonstrate the completeness of leachable monitoring.

What is the practical difference between a "Leachable" and a "Migrant" according to USP 1664?

USP <1664> introduces an important distinction: leachables result from direct contact between the formulation and the primary or secondary packaging components. Migrants, on the other hand, are substances that pass through a physical barrier from secondary or tertiary packaging (for example, label ink migrating through a plastic bottle). Both must nevertheless be assessed with the same level of safety rigor.

Why is USP 1664 considered an "informative" chapter?

Although it has been officially in force since December 2020 , USP <1664> is a chapter with a number above 1000, which means it provides recommendations and methodological frameworks. However, for regulatory authorities (such as the FDA), its application is often essential to demonstrate the safety of high-risk dosage forms such as inhalers (OINDP) or injectables.

What are the criteria for a simulation study to be valid?

To be considered valid, the study must demonstrate that the concentration of each potential leachable in the actual product will be less than or equal to the concentration found in the simulated extract. The chosen solvent must accurately simulate the extractive power of the actual formulation.

How can I get a quote from FILAB?

To obtain a quote, you can contact our teams via our contact form, by phone, or by email.
All you need to do is send us your requirements (material type, analysis requested, applicable standard, urgency, sample quantity, etc.). We will then send you a tailored technical and pricing proposal within 24-48 hours.

What is the typical turnaround time for analyses?

Lead times vary depending on the nature of the analysis and the complexity of the expert assessment project.
However, FILAB is committed to providing fast turnaround times adapted to your constraints and industrial urgencies.

The filab advantages
A highly qualified team
A highly qualified team
Responsiveness in responding to and processing requests
Responsiveness in responding to and processing requests
A COFRAC ISO 17025 accredited laboratory
A COFRAC ISO 17025 accredited laboratory
(Staves available on www.cofrac.com - Accreditation number: 1-1793)
A complete analytical facility of 5,200m²
A complete analytical facility of 5,200m²
Tailor-made support
Tailor-made support
Video debriefing available with the expert
Video debriefing available with the expert
Anaïs DECAUX Customer Support Manager
Ask for your quote