Testing Laboratory According to USP 661-2

Chemical analysis Material characterization Problem solving
More than 140 people
More than 140 people at your service
5200 m² laboratory
5200 m² laboratory + 99% of services are provided in-house
Accredited laboratory
Accredited laboratory COFRAC ISO 17025

USP Chapter 661.2 applies specifically to the primary plastic packaging components and systems of finished drug products, whether vials, bags, prefilled syringes, cartridges, or any other packaging in direct contact with the product.

It covers the sum of the packaging components that together contain the drug product, including closures (rubber stoppers, aluminum seals, laminated caps).

As a manufacturer, you want to carry out analyses according to USP 661-2

What tests are required according to USP 661-2?

USP 661-2 defines several categories of tests, the application of which depends on the type of packaged dosage form and the characteristics of the packaging system. The tests are based on the use of standardized extraction solutions, including solution C1 (purified water), selected according to the nature of the drug product and the conditions of use. The aqueous extract is obtained by filling the system to its nominal capacity, then subjecting it to a controlled heat treatment.

Test / Parameter

Oral & topical dosage forms

All other forms

UV absorbance (230–360 nm)

Required

Required

Acidity / Alkalinity

If liquid product

If liquid product

Total organic carbon (TOC)

Required

Required

Appearance of the solution (color + clarity)

Required

Required

Total terephthaloyl groups

PET / PETG only

PET / PETG only

Ethylene glycol

PET / PETG only

PET / PETG only

In vitro biological reactivity (USP <87>)

Not required

Required

Chemical suitability assessment (E&L)

Risk-based approach

Risk-based approach

Spectral transmission

If light protection

If light protection

FILAB’s laboratory supports you with your analyses according to USP 661-2

FILAB’s Analytical Approach

FILAB offers a complete qualification service for plastic packaging systems according to USP <661.2>, from the preparation of Solution C1 through to the delivery of the report. Our services are tailored to the nature of your system, your dosage form, and the requirements of your regulatory dossier.

Extract preparation and physicochemical testing

We handle the preparation of Solution C1 according to the extraction protocol appropriate for your system (121°C, 100°C, 70°C or 50°C depending on its thermal resistance), as well as all required physicochemical tests: UV absorbance (230–360 nm), acidity/alkalinity for liquid products, total organic carbon with criteria adjusted by volume, and visual assessment of appearance (color and clarity) according to USP reference standards.

Specific PET and PETG analyses

For polyethylene terephthalate systems, FILAB carries out the two required specific analyses: quantification of total terephthaloyl groups by multi-media extraction (alcohol, heptane, water) at 49°C for 10 days with spectrophotometric reading, and measurement of residual ethylene glycol by disodium chromotropate colorimetry after oxidation with periodic acid. These two analyses are critical for PET bottle dossiers intended for oral and injectable products.

Chemical Compatibility Assessment (E&L)

FILAB supports your extractables and leachables studies as part of the chemical suitability assessment required by USP <661.2>. Our experts advise you on study design according to the principles of USP <1663> and <1664> chapters, taking into account the risk associated with your dosage form and your regulatory requirements (FDA, EMA, ANSM).

Spectral Transmission Test

For packaging systems intended to protect the drug from light, FILAB measures spectral transmission between 290 and 450 nm using a UV-Vis spectrophotometer suitable for the analysis of plastic materials. The results are compared with the criteria in Table 2 of USP 661-2, adjusted according to the nominal volume and route of administration.

Our technical capabilities for analysis according to USP 661-2

To provide you with reliable analyses and interpretations, FILAB has a comprehensive analytical platform suited to analysis. This includes in particular:

GC-MS

LC-HRMS, LC-Orbitrap

LC-HRMS, LC-QTOF

ICP-MS, ICP-MS/MS & ICP-AES

SEM-EDX

  • the GC-MS, HPLC or UHPLC/MS/MS for the detection, identification, and quantification of organic compounds present in solvents, UV stabilizers, antioxidants, colorants, inks, detergent residues, sterilization residues, polymer residues… that have been extracted and/or released from the material by a standardized simulant
  • the ICP-AES and ICP-MS particularly suited to mineral or metallic contaminants or additives, such as heavy metals, mineral or metallic fillers, colorants…
  • microscopy SEM-EDX, a truly rapid and versatile diagnostic tool for assessing the material surface condition after aging, and for observing particles, deposits…

Associated services offered by the FILAB laboratory

Chemical characterization of materials and their properties used for your packaging

Physicochemical tests (defined according to the type of medicinal product and the type of plastic)

Migration test

Analysis of an unknown particle and comparison with the packaging or delivery material

Study of the device’s physical properties: thicknesses, porosity

Analysis of hazardous substances

Analysis of the purity of additives

Why choose FILAB for your analyses according to ISO 661-2?

  • COFRAC ISO 17025 accreditation and GMP environment
    Guarantees technical expertise, the traceability of our measurements, and the enforceability of our analytical results with French and European regulatory authorities, as well as the U.S. FDA.
  • Comprehensive multi-technique analytical platform
  • Mastery of regulatory thresholds (AET, SCT, etc.)
  • Structured reports for your regulatory submissions
    Each FILAB report is structured for direct integration into your submissions: CTD Module 3, IMPD, STED, BER, 510(k) or PMA dossier. Our deliverables include detailed operating conditions, annotated chromatograms, identification/quantification tables, and toxicological assessment of the detected compounds.

Our FAQ

What is the difference between USP <661.1> and USP <661.2>?
  • USP <661.1> applies to plastic materials tested individually such as pellets, films, or polymer parts.

  • USP <661.2> applies to the complete packaging system (bottle, bag, syringe with its closure) in direct contact with the finished drug product.

These two approaches are recognized by the USP as equivalent for demonstrating the compliance of a pharmaceutical packaging system.

Does my packaging system need to comply with both USP <661.1> and USP <661.2>?

No, these are two alternative pathways.

The requirements of USP <661.1> are considered met if the materials are used in a packaging system that already meets the requirements of USP <661.2>.

Which extraction condition should be used to prepare Solution C1?

The protocol is tiered according to the system’s thermal resistance:

  • 121°C for 30 min (standard autoclave condition).

  • 100°C for 2 h if the system cannot withstand 121°C.

  • 70°C for 24 h if the system cannot withstand 100°C.

  • 50°C for 72 h for the most heat-sensitive systems (official new update from December 2025).

Are extractables and leachables (E&L) studies mandatory?
  • USP <661.2> requires a risk-based chemical suitability assessment for all dosage forms.

  • For high-risk dosage forms (injectables, inhaled products), comprehensive studies according to USP <1663> and USP <1664> chapters are generally expected by regulatory authorities.

How can I get a quote from FILAB?

To get a quote, you can contact our teams via our contact form, by phone, or by email.
All you need to do is send us your requirements (material type, analysis requested, any applicable standard, urgency, number of samples, etc.). We will then send you a tailored technical and pricing proposal within 24-48 hours.

What is the typical turnaround time for analyses?

Lead times vary depending on the nature of the analysis and the complexity of the expert assessment project.
However, FILAB is committed to providing fast turnaround times adapted to your constraints and industrial urgencies.

The filab advantages
A highly qualified team
A highly qualified team
Responsiveness in responding to and processing requests
Responsiveness in responding to and processing requests
A COFRAC ISO 17025 accredited laboratory
A COFRAC ISO 17025 accredited laboratory
(Staves available on www.cofrac.com - Accreditation number: 1-1793)
A complete analytical facility of 5,200m²
A complete analytical facility of 5,200m²
Tailor-made support
Tailor-made support
Video debriefing available with the expert
Video debriefing available with the expert
Anaïs DECAUX Customer Support Manager
Ask for your quote