Develop and validate your LC-MS/MS analytical methods
Bringing a pharmaceutical, biopharmaceutical, cosmetic, or chemical product to market requires reliable, sensitive analytical methods specific to the matrix being studied. When no method exists, when it needs to be optimized, or when it must be shown to meet regulatory expectations, working with a specialized laboratory helps secure results and reduce project timelines. An expert laboratory supports you in method development, optimizing chromatographic and detection conditions, and then method validation according to the applicable guidelines, including ICH Q2 and, depending on the case, USP 233. This approach applies to the quantification of active ingredients, impurity testing, stability studies, leachables and extractables studies, and the quantification of regulated substances.
Addressing complex analytical challenges
LC-MS/MS analysis is particularly well suited to complex matrices and trace-level quantification needs. It can be used for the quantification of active compounds, impurity testing and quantification, monitoring degradation products in stability studies, identifying unknown compounds to support investigations, and analyzing leachable substances. Depending on the objectives, the laboratory can also combine this approach with liquid chromatography coupled to other detectors such as LC-UV, LC-RI, LC-CAD, or LC-ELSD, as well as advanced characterization techniques. For related needs, you can also explore our expertise in purification method development.
Structuring method development
The project begins with the collection of relevant data: product composition, matrix, target analytes, specifications, timeline constraints, and regulatory requirements. Based on these elements, the laboratory establishes a method development plan including sample preparation, selection of the column, mobile phase, gradient, MS/MS transitions, and performance criteria. Successive tests aim to obtain a robust, selective method suited to its intended use. To learn more about this stage, you can visit our dedicated page on analytical method validation.
Integrating regulatory requirements
Depending on the nature of the product and the project, the laboratory can structure its analytical work in line with recognized standards such as ICH Q2 for analytical method validation and USP 233 for certain elemental impurity analysis. Specific needs may also involve ICH Q3D for the determination of metals and other elemental impurities in pharmaceutical products. This regulatory expertise helps produce data that can be used in your development, qualification, or release dossiers.
Why entrust your project to an expert laboratory
Relying on an independent, technically equipped laboratory gives you rapid access to the skills, equipment, and procedures needed to ensure the success of your analytical project. Support can cover feasibility studies, test plan definition, selection of the instrumental technique, qualification of method performance, analytical transfer, and documentation support. This setup is particularly relevant for manufacturers who need to move quickly in R&D, process optimization, or regulatory control, without tying up internal resources for the long term.
Relying on complementary technical resources
The choice of technique depends on the analyte/matrix pair and the required level of performance. In addition to LC-MS/MS, methods such as LC-QTOF/MS can be used for structural identification, GC-MS or HS-GC/MS for volatile and semi-volatile compounds, ICP-MS, ICP-MS/MS or ICP-AES for elemental impurities, and ion chromatography for certain mineral species.
Validate and transfer the method
Once the analytical conditions have been stabilized, method validation demonstrates the method’s ability to produce reliable results. Depending on the context, the parameters assessed include specificity, linearity, range, accuracy, repeatability, intermediate precision, limits of detection and quantification, and robustness. The laboratory can then support method transfer to your production or control site to ensure analytical continuity between development and routine use.
Covering a broad range of analytical needs
Beyond LC-MS/MS, an expert laboratory can address related issues: elemental impurity testing by ICP-MS, ICP-MS/MS or ICP-AES, stability and chemical compatibility studies, extractables and leachables analysis, container-closure migration tests, cleaning residue analysis, or technical training needs. To strengthen your team’s skills, method development training can also be a useful lever.
Improve efficiency and secure your timelines
Outsourcing your analytical methods allows you to quickly mobilize specialized expertise, state-of-the-art equipment, and structured documentation practices without burdening your internal organization. It is a solution suited to absorbing a temporary workload, speeding up an R&D project, addressing a complex issue, or preparing a regulatory submission. Support can range from targeted literature review to method transfer, with a results-oriented approach. For very specific needs related to the analytical cleanliness of processes, also see ISO 19227 method validation.