Controlling the Risk of Elemental Impurities in Your Pharmaceutical Batches

In the pharmaceutical industry, the presence of heavy metals and elemental impurities can jeopardize batch release, delay a regulatory submission, or trigger a quality nonconformity. The challenge is not only analytical: it also involves controlling raw materials, excipients, active pharmaceutical ingredients, process water, packaging components, and finished products. A pharmaceutical analysis approach aligned with the expectations of ICH Q3D makes it possible to identify the elements to monitor, verify their content, and document the compliance of your products. Commonly targeted elements include arsenic, cadmium, mercury, and lead, as well as nickel, cobalt, vanadium, antimony, copper, chromium, and molybdenum. To explore instrumental approaches suited to the sector, see our Pharmaceutical ICP Analysis page.

Target the Relevant Element Classes

ICH Q3D structures the assessment of elemental impurities by class. Class 1 elements include arsenic, cadmium, mercury, and lead. Class 2 elements include cobalt, nickel, and vanadium. Class 2B groups elements such as silver, gold, thallium, palladium, platinum, iridium, osmium, rhodium, ruthenium, and selenium. Class 3 may concern antimony, barium, lithium, chromium, copper, tin, and molybdenum. The selection of analytes depends on the risk assessment, the materials used, and the manufacturing process.

Use ICP Techniques Suited to the Target Thresholds

The determination of elemental impurities relies on reference techniques such as ICP-MS, ICP-MS/MS, and ICP-AES. These tools make it possible to quantify metallic traces in pharmaceutical matrices with quantification limits that can go down to 0.1 ppm depending on the element and the matrix. ICP-MS/MS is particularly useful when spectral interferences must be controlled. ICP-AES may be selected for certain assays when the expected levels and the matrix allow it. For mercury, a cold vapor analyzer may also be used depending on the analytical need.

Benefit from Regulatory and Methodological Expertise

An expert laboratory brings more than just a numerical result. It helps build the control strategy, choose the most relevant technique, interpret the data, and document compliance within a demanding regulatory framework. Support can include method development, analytical validation according to USP 233 or ICH Q2, as well as training on the requirements of ICH Q3D. This approach is particularly useful during an analytical transfer, a risk review, an OOS investigation, or a formulation change.

Relying on an Expert Laboratory for Analysis and Validation

An expert laboratory supports pharmaceutical manufacturers in method development, quantification of the 24 elemental impurities covered by ICH Q3D, and analytical validation according to the applicable references, including USP 233 and ICH Q2. This expertise covers investigations on raw materials, intermediates, gels, finished dosage forms, and complex matrices. It makes it possible to adapt the analytical strategy to the product, the matrix, the expected sensitivity level, and the client’s quality objectives. Support can also include R&D assistance, nonconformity investigations, assessment of contamination from processes or packaging, as well as the development of tailor-made methods for routine or validation needs.

Adapt the Control Plan to Your Product

The control plan must be sized according to the nature of the product: active ingredient, excipient, semi-solid form, solution, gel, or finished product. It may also include investigations on process water, cleaning residues, packaging, or contact materials. For related residual contamination issues, you can also consult our expertise on Residus Metaux Lourds Iso 19227.

Prepare Samples Properly to Ensure Reliable Results

The quality of the result depends heavily on sample preparation. Microwave digestion can be implemented to solubilize the matrix and ensure robust measurement. This step is essential for finished products, gels, complex formulations, or materials likely to introduce contaminants. Depending on the case, the laboratory can also address related issues involving particles or material contamination, for example via the page Unknown Particles in Pharmaceutical Products.

Secure Your Quality, Validation, and R&D Projects

Using an ISO 17025 accredited laboratory by COFRAC for pharmaceutical and cosmetic activities is an asset for making your analytical data more reliable. This setup can meet routine needs as well as specific requests: failure investigation, trace analysis of catalysts, packaging material assessment, or support for optimizing industrial processes. In some cases, complementary expertise on materials and formulations may also be relevant, such as our Polymer Rheology Analysis Laboratory for the Pharmaceutical Industry.

Define, submit, analyze, validate

To start a service, it is necessary to specify the nature of the matrix, the target elements, the regulatory context, the expected thresholds, and the final need: release testing, risk assessment, method development, validation, or investigation. The laboratory can then propose a suitable analytical strategy, carry out the tests, and deliver actionable results for your quality, control, or regulatory affairs teams. To move forward efficiently: define the analytical scope, submit product and process information, analyze the samples with the appropriate technique, validate the method if necessary, document the compliance of your batches.

Frequently asked questions

How can you ensure ICH Q3D compliance for your raw materials and pharmaceutical batches?

To secure your batches in line with ICH Q3D, you first need to identify the elements at risk based on the formulation, process, equipment, and packaging, then implement a heavy metals analysis suited to the matrix. An expert laboratory can then perform the assay, interpret the results against the applicable thresholds, and provide support in method development or validation to make your quality controls more reliable.

Which elemental impurities can be tested in a medicinal product according to ICH Q3D?

The elemental impurities targeted under ICH Q3D cover up to 24 elements, grouped by risk class. The most frequently monitored are lead, mercury, arsenic, and cadmium, but the assessment may also include nickel, cobalt, vanadium, antimony, chromium, copper, tin, or catalytic metals such as palladium and platinum.

What analytical methods should be used to quantify heavy metals in complex pharmaceutical matrices?

The most widely used techniques are ICP-MS, ICP-MS/MS, and ICP-AES. The choice depends on the target elements, the matrix, potential interferences, and the levels to be achieved. Appropriate sample preparation, especially digestion, is essential to obtain reliable, actionable results in a pharmaceutical setting.

Why entrust your elemental impurity analysis to Filab laboratory?

Entrusting your analysis to Filab laboratory helps secure both the measurement, regulatory compliance, and interpretation of results. You benefit from support in choosing techniques, method validation, handling complex matrices, and the quality documentation needed for your industrial challenges.

What steps should you take to launch a heavy metals analysis on your pharmaceutical batches?

To launch an analysis, you need to define the matrix, the elements to be assayed, the regulatory objectives, and the target thresholds, then provide this information to an expert laboratory. The laboratory can then propose the appropriate protocol, carry out the assays, and support validation or interpretation of the results according to your quality and production constraints.
The filab advantages
A highly qualified team
A highly qualified team
Responsiveness in responding to and processing requests
Responsiveness in responding to and processing requests
A COFRAC ISO 17025 accredited laboratory
A COFRAC ISO 17025 accredited laboratory
(Staves available on www.cofrac.com - Accreditation number: 1-1793)
A complete analytical facility of 5,200m²
A complete analytical facility of 5,200m²
Tailor-made support
Tailor-made support
Video debriefing available with the expert
Video debriefing available with the expert
Anaïs DECAUX Customer Support Manager
Ask for your quote