The problem?
As part of its industrial boiler production activities, one of our customers is currently involved in a dispute with its supplier following a labeling error on valves equipped with sleeves.
In order to remove any doubt about the conformity of the materials received, it wishes to confirm that the seals inside the valves are indeed made of FKM (fluoroelastomer)—a material known for its high chemical and thermal resistance—and not EPDM (ethylene propylene diene monomer), which is more suitable for aqueous or less aggressive environments, as indicated on the label.
In order to carry out this study, FILAB developed an analytical approach using Fourier Transform Infrared Spectroscopy (FTIR), a chemical analysis technique that can identify the molecular structure of many materials, particularly for the study of polymers.
Determine the physical and chemical composition of the valve sleeve seal.
Objective:
This step aims to confirm that the valve and its seal have the necessary characteristics to transport the fluid passing through the valve, namely a synthetic gas produced by the carbonization of wood, a complex mixture containing corrosive and volatile compounds.
Another purpose of this study is to verify that the seal has not deteriorated during use.
Approach:
For this study, the technique used is Fourier Transform Infrared Spectroscopy (FTIR) between 4000 and 400 cm-1. This technique involves subjecting the sample to infrared radiation: each type of chemical bond absorbs a specific wavelength, which provides a true "chemical fingerprint" of the material.
With this analytical technique, the material is identified in two stages.
The characteristic peaks are extracted to search for the corresponding bonds in reference tables. The continuous spectrum is then compared to a spectral database, which allows the nature of the material to be determined accurately through maximum correspondence calculations.
At the same time, FTIR analysis allowed us to check for any abnormal degradation of the seal by comparing used samples.
Comparative study of the two joints - compliance study
Spectroscopic analysis of the sample reveals several characteristic absorption bands, including C-F and C-C bond stretching (between 1393 and 1080 cm⁻¹), CF and CH vibrations (between 829 and 720 cm⁻¹), and CF₂ group deformations groups (around 634 and 607 cm⁻¹).
These signals are characteristic of a fluorinated elastomer. The results as a whole therefore lead to the conclusion that the seal analyzed is made of a material of the FKM (fluoroelastomer) type, commonly used for its chemical and thermal resistance properties.
Comparison of the FTIR spectrum of the customer sample (blue) and a "FKM" reference (black).
In addition, to assess any abnormal degradation, a comparison was made between samples of seals in service and new samples. The results show that the used seal retains the same chemical characteristics as the new seal: no alteration or degradation of the material was detected.
Conclusion of the comparative study
Thanks to the analysis carried out using Fourier Transform Infrared Spectroscopy (FTIR), our teams were able to confirm the exact nature of the polymer used in the seals: it was indeed FKM (fluoroelastomer) and not EPDM, as suggested by the supplier's labeling.
This precise identification made it possible to remove any doubt about the conformity of the parts and rule out the possibility of a material error.
Furthermore, a comparison between new and used seals showed no significant chemical degradation: the material retained all its properties over time.
Our customer was able to continue production without concern, with no impact on the safety or performance of its facilities.
This study perfectly illustrates how material characterization goes beyond simple testing to ensure industrial safety and maintain trust between partners.
Other case studies you may be interested in
Comparison of the quality of a metal oxide coating for a ski mask using AFM
The customer wants to compare the quality of metal oxide for his ski mask. Learn more +Produits pharmaceutiques
L’un de nos clients a détecté la présence de particules inconnues dans ses produits pharmaceutiques lors des contrôles de qualité Learn more +Corrosion rate: the strategic choice of materials
One of our customers wanted to test the corrosion resistance of their heat exchangers. Learn more +Laboratory specializing in analysis and expertise for industrial companies
Contact us
Our services are reserved for professionals.Frequently asked questions
How can you check whether an industrial seal is made of FKM or EPDM?
Fourier transform infrared spectroscopy (FTIR) distinguishes an FKM seal from an EPDM seal through its chemical signature. The laboratory examines the material’s absorption bands and compares its spectrum with reference spectra to identify the elastomer family. Explore FTIR analysis.
Which infrared markers help identify FKM?
FKM shows absorption bands characteristic of a fluorinated elastomer, particularly those associated with carbon–fluorine bonds and CF₂ groups. Identification relies on the full infrared spectrum and comparison with a known reference to support the assignment to an FKM material.
How can chemical degradation be investigated in a used seal?
Comparing the FTIR spectra of a new seal and a seal in service helps reveal changes in chemical structure. In the FILAB study, no significant chemical change was detected between the samples compared. This finding relates to the characteristics accessible through this analysis.
What did the FILAB valve seal study establish?
The study confirmed that the seals analysed were made of FKM, despite labelling that suggested EPDM. Comparison of new and used seals also revealed no significant chemical degradation. These results gave the client objective evidence to clarify the labelling discrepancy with its supplier.
How can you check whether a seal material is suitable for the fluid it carries?
Assessing seal compatibility requires knowledge of the material, the fluid composition and exposure conditions, particularly temperature and contact time. Polymer identification can be supplemented by tests representative of actual use to investigate possible deterioration. Read about material–fluid compatibility.