Halogen analysis laboratory in accordance with IEC 63355

Chemical analysis Problem solving R&D support
More than 140 people
More than 140 people at your service
5200 m² laboratory
5200 m² laboratory + 99% of services are provided in-house
Accredited laboratory
Accredited laboratory COFRAC ISO 17025

As an industrial company, you want to carry out halogen analysis in accordance with IEC 63355

What does IEC 63355 say?

The IEC 63355 standard is an international standard developed by the International Electrotechnical Commission (IEC), which prepares and publishes international standards for electrotechnical and electronic technologies. This regulation specifies a method for determining the halogen content of products or components of cable management systems (CMS) made entirely or partly of combustible material(s). Halogens include elements such as chlorine, fluorine, bromine and iodine, which may be present in polymers, wiring materials, textiles and other industrial products.

norme iec 63355

What is the scope of IEC 63355?

This standard is particularly relevant for industries such as electronics, where insulating and wiring materials must be analyzed to verify that they comply with the maximum permissible halogen content thresholds. It also applies in sectors such as aerospace, automotive, medical devices and nuclear, where safety is paramount.

Halogen analysis according to IEC 63355 and PMUC analysis

A PMUC item is a product or material that has been approved after PMUC analysis for use in nuclear power plants, in accordance with the specific safety requirements of this industry. These materials must not only perform well, but also be safe in the event of incidents such as fires. The absence of hazardous substances, including certain halogens, is essential to prevent the production of corrosive or toxic gases that could threaten the integrity of facilities and the safety of people.

The IEC 63355 standard specifies methods for measuring halogen content, making it possible to ensure that the materials tested comply with safety thresholds. For PMUC items, these analysis are crucial, as the presence of chlorine, fluorine, bromine or iodine could release acidic gases during combustion. These gases may damage ventilation systems, electronic equipment and human health if released into a confined environment.

FILAB supports industrial companies with halogen analysis in accordance with IEC 63355

Why carry out halogen analysis in accordance with IEC 63355?

When exposed to high temperatures or combustion, halogens can release corrosive and toxic gases, creating health risks and material damage. The IEC 63355 standard is therefore crucial to ensure material safety, prevent the release of hazardous gases and comply with increasingly strict regulations on environmental impact and product safety.

Carrying out analysis in accordance with IEC 63355 makes it possible to:

  • Strengthen product safety by avoiding the use of materials that could release hazardous gases.
  • Reduce environmental risks, as halogens can have harmful effects on wildlife and flora when released into the atmosphere.
  • Ensure regulatory compliance and meet customer expectations in terms of safety and sustainability.

Why choose FILAB for your halogen analysis in accordance with IEC 63355?

The FILAB laboratory has a state-of-the-art analytical platform and highly skilled staff to meet the requirements of IEC 63355 and support industrial companies in halogen analysis according to IEC 63355.

Whatever your industry sector, turn to the FILAB laboratory for your halogen analysis in accordance with IEC 63355.

Our technical resources for halogen analysis in accordance with IEC 63355

The determination of halogens in CMS according to IEC 63355 is carried out by combustion and subsequent analysis of the combustion product by Ion Chromatography (IC or CIC).

The filab advantages
A highly qualified team
A highly qualified team
Responsiveness in responding to and processing requests
Responsiveness in responding to and processing requests
A COFRAC ISO 17025 accredited laboratory
A COFRAC ISO 17025 accredited laboratory
(Staves available on www.cofrac.com - Accreditation number: 1-1793)
A complete analytical facility of 5,200m²
A complete analytical facility of 5,200m²
Tailor-made support
Tailor-made support
Video debriefing available with the expert
Video debriefing available with the expert
Clément BOENARD Head of Inorganic Chemistry Department
Ask for your quote